Power Supply Which Requiries an AC Withstanding TestSURGE ABSORBERS
Application:SW power supply, inverter power supply, power supply of office and home appliance
IEC62368-1 requires series usage of MOV ※ 1) and GDT ※ 2) for surge protection in the primary circuits of equipment.
※1) The MOV complies with the requirements of AnnexG.8.
※2) The GDT complies with :
*the electric strength test for BASIC INSULATION ; and
*the external Clearance and Creepage distance requirements for basic insulation.
Recommended parts
AC125V | AC250V | ||
---|---|---|---|
Normal mode(Between L1 and L2) | DSANR‐1 DSAZR1‐301L |
DSANR‐3 DSAZR2‐501M |
|
Common mode (Between L1/L2 and GND) AC withstanding voltage test condition |
Test is not required |
DSANR‐1, DSAZR1‐301L | DSANR‐3, DSAZR2‐501M |
AC1,000V-1min. AC1,200V-3sec. |
DSANR‐4, DSAZR1‐242M CDA70-272M+MOV1) (MOV)1) DA53‐272M+MOV1) (MOV)1) DSA‐242M+MOV1) (MOV)1) DE37‐272M+MOV1) (MOV)1) |
DSAZR2‐242M CDA70‐272M+MOV2) (MOV)2) DA53‐272M+MOV2) (MOV)2) DSA‐242M+MOV2) (MOV)2) DE37‐272M+MOV2) (MOV)2) |
|
AC1,500V-1min. | DSANR‐5, DSAZR1‐302M CDA70-302M+MOV1) (MOV)1) DA53‐302M+MOV1) (MOV)1) DSA‐302M+MOV1) (MOV)1) DE37‐302M+MOV1) (MOV)1) |
DSANR‐5, DSAZR2‐302M CDA70‐302M+MOV2) (MOV)2) DA53‐302M+MOV2) (MOV)2) DSA‐302M+MOV2) (MOV)2) DE37‐302M+MOV2) (MOV)2) |
|
AC1,800V-3sec. | DSANR‐6, DSAZR1‐362M CDA70-362M+MOV1) (MOV)1) DA53‐362M+MOV1) (MOV)1) DSA‐362M+MOV1) (MOV)1) DE37‐362M+MOV1) (MOV)1) |
DSANR‐6A, DSAZR2‐362M CDA70‐362M+MOV2) (MOV)2) DA53‐362M+MOV2) (MOV)2) DSA‐362M+MOV2) (MOV)2) DE37‐362M+MOV2) (MOV)2) |
|
AC2,000V-1min. | DSANR‐10B, DSAZR1‐452M DSA‐402M+MOV1) (MOV)1) DE37‐452M+MOV1) (MOV)1) |
DSANR‐10B, DSAZR2‐452M DSA‐402M+MOV2) (MOV)2) DE37‐452M+MOV2) (MOV)2) |
MOV1) : Varistor voltage:More than 220V(UL recognized:More than 270V)
MOV2) : Varistor voltage:More than 470V
"+" : electrically connected series by gas discharge tube and MOV